Product Description
Category 6 unshielded cables are used in structured cabling data transmission cables; carry digital, voice, data and video signals for all Class E links and Category 6 applications, including ISDN, 10 Megabit Ethernet, 100 Megabit Fast Ethernet, 1000 Megabit Ethernet, 4/16Mbit/s Token Ring, TP-PMD/TP-DDI 125Mbit/s, ATM 155Mbit/s, ATM 622Mbit/s.
Product Introduction
Application
Meets or exceeds requirements of ANSI/TIA-568-C.2 Category 6 and ISO 11801 2nd Edition Class E channel standards.
Meets or exceeds requirements of ANSI/TIA-568-C.2 and IEC 61156-5 Category 6 component standards.
Meets requirements of IEEE 802.3af and IEEE 802 3at for PoE applications
Third party tested to comply with ANSI/TIA/EIA-568-C.2
Descending length cable markings enable easy identification of remaining cable which reduces installation time and cable scrap.
Color Availabillity:Additional cable colors available.
Detailed Photos
Electrical Characteristics
Impedance:1-250MHz 100±15(Ohms)
Rated temperature:75ºC
DC Resistance Unbalance(%):Max2.5
DC resistance 20ºC:8.4(Ohms/100m)
Pair-to-Gruond Capacitance Unbalance:330(pF/100M)
Insulation Resistance:>5000MΩ*Km
Dielectric strength:DC 2500V 2S
Product Features
Meets ANSI/TIA-568.2-D 250MHz test and can be extended to 350MHz
Crossbone isolation between pairs effectively reduces crosstalk and increases structural stability
Provide cable length marking to reduce waste
Supports high-speed transmission of voice, data and video signals
Easy and time-saving termination
Conductor |
|
Conductor |
Solid Bare Copper 24AWG |
Insulation |
HDPE |
Total number of insulated conductors |
8,txisted in 4 pairs |
Color code |
White-Blue/Blue,White-Orange/Orange,White-Green/Green,White-Brown/Brown |
Individual pair shield |
None |
Overall shield |
None |
Drain wire |
None |
Product Parameters
Specifications, dimensions, installation requirements
Number of cable pairs |
4 pairs |
Wire Pair Color |
White-blue, blue, white-orange, orange, white-green, green, white-brown, brown |
Conductors |
Structure |
Single strand |
Material |
Annealed Round Copper |
Wire gauge |
24AWG |
Insulation |
Core wire outside diameter |
0.93±0.10mm |
Material |
HDPE+color masterbatch |
Color |
color strip |
Twisted |
Color of core wire |
White-blue/blue |
White-orange/orange |
White-green/green |
White-brown/brown |
Cross skeleton material |
PE |
Rip cord |
150D Polyester straight tow |
Sheathing |
Material |
PVC |
Outer diameter |
6.0±0.3mm |
Average thickness |
0.6±0.1mm |
Printing |
SHIP-TECH SYSTEM CABLE UTP CAT.6 4PAIRS 24AWG ISO11801
D165-E HSYV-6 001M…305M |
Roll Forming Method |
Reelex II |
Installation temperature |
0ºC~+60ºC |
Use and storage temperature |
-20ºC~+60ºC |
Cable reference net weight |
11.2kg/305m |
Mechanical properties
elongation at break of a conductor |
≥15% |
elongation at break of insulation |
≥300% |
tensile strength of insulation |
≥16MPa |
tensile strength of sheath before aging |
≥13.5MPa |
tensile strength of sheath after aging(100ºC±2ºC,168h) |
≥12.5MPa |
change rate of tensile strength of sheath after aging |
±20% |
elongation at break before aging of sheath |
≥150% |
elongation at break after aging of sheath(100ºC±2ºC,168h) |
≥125% |
change rate of fracture elogation after aging of sheath |
±20% |
the insulation core is broken or mixed |
uninterrupted line without mixed line |
Electrical performance
Characteristic impedance |
100±15Ω |
Single Conductor DC Resistance |
≤9.5Ω/100m |
DC resistance imbalance within the wire pair |
≤2.0% |
Dielectric Strength DC Conductor-to-Conductor |
1000V,1min No breakdown |
Propagation delay difference |
≤45ns/100m |
Propagation delay |
≤536ns/100m |
Operating capacitance |
≤5.6nF/100m |
Rated transmission rate (NVP) |
68% |
Insulation resistance |
≥5000MΩ·km +20ºC DC (100-500)V |
transmission performance
Frequency |
IL(max) |
RL(min) |
NEXT(min) |
PSNEXT(min) |
ACR-F(min) |
PSACR-F(min) |
(MHZ) |
(dB/100m) |
(dB) |
(dB) |
(dB) |
(dB/100m) |
(dB/100m) |
1 |
2.0 |
20.0 |
75.3 |
72.3 |
67.8 |
64.8 |
4 |
3.8 |
23.0 |
66.2 |
63.2 |
55.7 |
52.7 |
10 |
6.0 |
25.0 |
60.3 |
57.3 |
47.8 |
44.8 |
16 |
7.6 |
25.0 |
57.2 |
54.2 |
41.7 |
38.7 |
20 |
8.5 |
25.0 |
55.7 |
52.7 |
43.7 |
40.7 |
31.25 |
10.7 |
23.6 |
52.8 |
49.8 |
37.9 |
34.9 |
62.5 |
15.4 |
21.5 |
48.3 |
45.3 |
31.8 |
28.8 |
100 |
19.8 |
20.1 |
45.3 |
42.3 |
27.8 |
24.9 |
200 |
29.0 |
18.0 |
40.7 |
37.7 |
21.7 |
18.7 |
250 |
32.80 |
17.3 |
39.3 |
36.3 |
19.8 |
16.8 |
Flame retardant performance
Comply with GB / T 18380.22-2008 vertical flame spread test of single insulated thin wire and cable - diffusion flame test method
Distance between the lower edge of the upper support and the start of charring |
>50 mm |
Distance between the lower edge of charring and the lower edge of the upper support |
≤540 mm |
Packing box specification:
Length * width * height (CM) |
39*39*23cm |
Cable length |
305m/box |
Full container reference weight |
12.2kg |
FAQ
Q1: How can I believe that your product is of good quality?
A1: We guarantee that all products are original products.We provide a complete test report.
Q2: When can I get a quote?
A2: We will usually quote you within 24 hours after receiving your inquiry. If you really want to get a quotation and more other questions, you can contact us via trademessage or email.
Q3: Why choose you?
Q3: As an Audited Supplier,we have a good reputation on our customers,because of the good quality,suitable price and good service.
Q4: What is your payment?
A4: T/T wire bank transfer.