Type: | Ethernet Switch |
---|---|
Ports: | 28 |
Management Port: | 1 Console Port |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
project | S3600V2-28TP-SI S3600V2-28TP-EI |
S3600V2-52TP-SI S3600V2-52TP-EI |
S3600V2-28TP-PWR-SI S3600V2-28TP-PWR-EI | S3600V2-52TP-PWR-SI S3600V2-52TP-PWR-EI | S3600V2-28F-EI | ||||||||
management port | 1 console port | ||||||||||||
Service port description | fixed port | 24 10/100Base-TX Ethernet ports, 2 1000Base-T and 1000Base-X SFP Combo ports, 2 1000Base-X SFP Gigabit Ethernet ports | 48 10/100Base-TX Ethernet ports, 2 1000Base-T and 1000Base-X SFP Combo ports, 2 1000Base-X SFP Gigabit Ethernet ports | 24 10/100Base-TX Ethernet ports, 2 1000Base-T and 1000Base-X SFP Combo ports, 2 1000Base-X SFP Gigabit Ethernet ports | 48 10/100Base-TX Ethernet ports, 2 1000Base-T and 1000Base-X SFP Combo ports, 2 1000Base-X SFP Gigabit Ethernet ports | 24 100Base-FX SFP Ethernet ports, 2 1000Base-T and 1000Base-X SFP Combo ports, 2 1000Base-X SFP Gigabit Ethernet ports | |||||||
optional module | 1000BASE-SX-SFP 1000BASE-LX-SFP 1000BASE-LH-SFP 1000BASE-ZX-LR-SFP 1000BASE-ZX-VR-SFP 100Base-FX-MM-SFP 100Base-FX-SM-SFP |
||||||||||||
exchange capacity | 64Gbps | ||||||||||||
Layer 2/3 forwarding rate | 9.6Mpps/14.1Mpps | 13.2Mpps/17.7Mpps | 9.6Mpps/14.1Mpps | 13.2Mpps/17.7Mpps | 9.6Mpps/14.1Mpps | ||||||||
exchange mode | Store and Forward mode | ||||||||||||
port | Supports IEEE 802.3x flow control (full duplex) Supports broadcast storm suppression based on port rate percentage Support pps-based broadcast storm suppression |
||||||||||||
port aggregation | LACP support Support manual aggregation Supports up to 128 aggregation groups, each group supports up to 8 ports |
||||||||||||
MAC address | Support black hole MAC Support setting the maximum number of port MAC learning |
||||||||||||
VLAN | Supports port-based VLANs (4K) Protocol-based VLAN support Supports MAC-based VLANs Support Voice VLAN Support Super VLAN Support PVLAN GVRP support Support VLAN VPN (QinQ), flexible QinQ |
||||||||||||
stack | Support IRF2 Intelligent Resilience Architecture Support distributed device management, distributed link aggregation Support distributed elastic routing (EI series) Supports stacking via standard Ethernet interfaces, etc. Supports local stacking and remote stacking |
||||||||||||
DHCP | Support DHCP Client/ DHCP Relay/ DHCP Snooping Support DHCP Server |
||||||||||||
IP routing | Support static routing, RIPv1/v2, RIPng Support OSPFv1/v2, OSPFv3 (EI series) Support IS-IS, IS-ISv6 (EI series) Support BGP, BGP4+ for IPv6 (EI series) Support policy routing, ECMP Support VRRP/VRRPv3 |
||||||||||||
MCE | Support MCE (Multi-CE) | ||||||||||||
multicast | Support IGMP Snooping v1/v2/v3, MLD Snooping v1/v2 Support multicast VLAN Support IGMP V1/V2/V3, MLD v1/v2, PIM-SM, PIM-DM, PIM-SSM, MSDP (EI series support) |
||||||||||||
reliability | Support STP/RSTP/MSTP protocol Support Smart Link Support Smart Link multi-instance BFD support Support RRPP |
||||||||||||
IPV6 | Support ND (Neighbor Discovery) Support ND snooping, ND proxy, ND detection Support PMTU Support IPv6 Ping, IPv6 Tracert, IPv6 Telnet, IPv6 TFTP Support manual configuration of Tunnel Support 6 to 4 tunnel Support ISATAP (Intra-site Automatic Tunneling Protocol) tunnel Support Auto-tunnel (ie Automatic IPv4 Compatible IPv6 Tunnel) |
||||||||||||
mirror | Support N:4 port mirroring Stream mirroring supported RSPAN (Remote Switched Port Analyzer, Remote Switched Port Analyzer) |
||||||||||||
QoS/ACL | ACL support | Support L2~L4 packet filtering function, provide based on source MAC address, destination MAC address, source IP address, destination IP address, port, protocol type, VLAN, etc. Support ACL based on source IPv6 address, destination IPv6 address, TCP/UDP port number, protocol type, etc. Supports time-based ACLs Supports bidirectional ACL policies in inbound and outbound directions Supports issuing ACLs based on VLANs |
|||||||||||
Support QoS | Supports limiting the rate at which the port receives packets and the rate at which it sends packets Supports 802.1p and DSCP priority re-marking of packets Support message redirection Support CAR function Supports 8 port output queues Support flexible queue scheduling algorithm, can be set based on port and queue at the same time, support SP, WRR, SP+WRR and other modes |
||||||||||||
safety features | User hierarchical management and password protection Support IEEE 802.1X authentication/centralized MAC address authentication Support Layer 2 Portal authentication/triple authentication Support AAA&RADIUS authentication Support the limit of the number of MAC address learning Support the binding of MAC address, port and IP Support SSH2.0 Support DoS attack prevention function Support ARP intrusion detection function Support port isolation Support MAC address black hole |
||||||||||||
management and maintenance | Support XModem/FTP/TFTP loading and upgrading Support command line interface (CLI), Telnet, Console port for configuration Support SNMPV1/V2/V3, WEB network management Support RMON 1, 2, 3, 9 groups of MIB Support IMC intelligent management center Support HGMPv2 cluster management Support system log, hierarchical alarm, debugging information output Support PING, Tracert Supports the detection and alarm of power-on POST, fan stall, overheating of PoE devices, etc. Support VCT (Virtual Cable Test) cable detection function Support DLDP (Device Link Detection Protocol, Device Link Detection Protocol) Support port loopback detection Support IPv6 host function family, realize IPv6 management |
||||||||||||
Dimensions (mm) width x depth x height |
440×260×43.6 440×420×43.6 (PWR series) |
||||||||||||
weight | S3600V2-28TP-SI, S3600V2-28TP-EI, S3600V2-28F-EI, S3600V2-52TP-SI, S3600V2-52TP-EI: 5kg S3600V2-28TP-PWR-SI, S3600V2-28TP-PWR-EI, S3600V2-52TP-PWR-SI, S3600V2-52TP-PWR-EI: 10kg |
||||||||||||
Input voltage | S3600V2-SI series non-POE switches only support AC power input, while S3600V2-SI series POE switches and S3600V2-EI series switches support AC power input and DC power input. AC: Rated voltage range: 100~240V AC.; 50/60Hz Maximum voltage range: 90~264V AC; 47/63Hz DC: Rated voltage range: -48~-60V DC. Maximum voltage range: -36~-72V DC. Input voltage range for POE power supply: -45~-55V DC Input voltage range when POE+ is powered: -55~-57VDC |
||||||||||||
Power consumption (at full load) | 26W 31W | 41W 43W | AC: 465W DC: 795W |
AC: 440W DC: 820W |
60W | ||||||||
Working temperature | 0~50ºC | ||||||||||||
Relative humidity of working environment (non-condensing) | 5%~90% |
We focus on the IDC data center field, have professional enterprise-level products, and provide complete planning and design solutions.
Main Application Scenarios:
Only applies to servers.
Delivery time : 15-20 working days after payment receipt confirmed (based on actual quantity). |
Original packaging to ensure product quality and safety. |
Professional goods shipping forwarder. |
We guarantee that all products are original and authentic. All support after-sales inspection. Regarding xFusion server, we can provide remote technical services and troubleshooting. In addition to new retail products. Others have used NEW BULK. We provide a complete test report. Please rest assured to buy. The stock is huge. Many products are not released in time. If you need more product quotations. You can email to contact us at any time. |
||||
Q1: How can I believe that your product is of good quality?
A1: We guarantee that all products are original products.We provide a complete test report.
Q2: When can I get a quote?
A2: We will usually quote you within 24 hours after receiving your inquiry. If you really want to get a quotation and more other questions, you can contact us via trademessage or email.
Q3: Why choose you?
Q3: As an Audited Supplier,we have a good reputation on our customers,because of the good quality,suitable price and good service.
Q4: What is your payment?
A4: T/T wire bank transfer.